Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-02-18 to 2010-02-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Recent, well documented GLP and guideline study.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
1-chloro-2,5-dimethoxy-4-nitrobenzene
EC Number:
230-086-7
EC Name:
1-chloro-2,5-dimethoxy-4-nitrobenzene
Cas Number:
6940-53-0
Molecular formula:
C8H8ClNO4
IUPAC Name:
1-chloro-2,5-dimethoxy-4-nitrobenzene

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
<= 8.61 µm
St. dev.:
0.026
Remarks on result:
other: RSD = 0.31 %
Percentile:
D50
Mean:
<= 76.9 µm
St. dev.:
1.36
Remarks on result:
other: RSD = 1.77 %
Percentile:
D90
Mean:
<= 195 µm
St. dev.:
4.2
Remarks on result:
other: RSD = 2.14 %

Any other information on results incl. tables

Dry dispersing system RODOS: Measurement starting with approximately 12 - 13 g powder for each test at a pressure of 1.5 bar. The measuring range of the optical system was set to lense R5 (0.5/4.5...875 µm).

Summary table

Run

X10

[µm]

X50

[µm]

X90

[µm]

1

8.63

77.76

191.93

2

8.62

77.67

193.96

3

8.58

75.36

199.97

Average

8.61

76.93

195.29

Standard Deviation

0.026

1.360

4.181

RSD [%]

0.31

1.77

2.14

 

The average particle size and standard deviation of the test item
1-Chloro-2,5-dimethoxy-4-nitrobenzene was

X10: ≤ 8.61 ± 0.026 pm
X
50: ≤ 76.9 ± 1.36 pm
X
90: ≤ 195 ± 4.2 pm


Applicant's summary and conclusion

Conclusions:
The Particle Size Distribution of the test item 1-Chloro-2,5-dimethoxy-4-nitrobenzene
was measured with Sympatec HELOS laser diffraction with dry dispersing system
RODOS.
The average and standard deviation of 3 determinations was:
X10: ≤ 8.61 ± 0.026 3m (RSD = 0.31 %)
X50: ≤ 76.9 ± 1.36 3m (RSD = 1.77 %)
X90: ≤ 195 ± 4.2 3m (RSD = 2.14 %)
Executive summary:

The Particle Size Distribution of the test item 1-Chloro-2,5-dimethoxy-4-nitrobenzene

was measured with Sympatec HELOS laser diffraction with dry dispersing system

RODOS.

The average and standard deviation of 3 determinations was:

X10: ≤ 8.61 ± 0.026 µm (RSD = 0.31 %)

X50: ≤ 76.9 ± 1.36 µm (RSD = 1.77 %)

X90: ≤ 195 ± 4.2 µm (RSD = 2.14 %)