Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil
Test temperature:
25degC
Details on study design: HPLC method:
Instrument: Agilent 1200 Series Liquid Chromatograph with Chemstation software
Column: Hyperclone CN (CPS) (25 cm x 4.6 mm internal diameter)
Column temp.: 25°C
Mob. phase comp.:Methanol:water (55:45 v/v)
Flow rate: 1.0 ml/min
Injection vol.: 20 µl
Detector: UV set at 210 nm


Key result
Type:
log Koc
Value:
ca. 3
Temp.:
25 °C

A calibration plot of log10k versus log10Koc was constructed for the reference standards. The logarithm of the capacity factor for the test substance was then calculated and the log10Koc value determined by interpolation. Ferrocene was thus determined to have a log10Koc value of 3.0 (equivalent Koc value = 1050)

Validity criteria fulfilled:
yes
Conclusions:
Ferrocene was determined to have a log10Koc value of 3.0 (equivalent Koc value = 1050).
Executive summary:

A calibration plot of log10k versus log10Kocwas constructed for the reference standards. The logarithm of the capacity factor for the test substance was then calculated and the log10Kocvalue determined by interpolation.

Ferrocene was thus determined to have a log10Kocvalue of 3.0 (equivalent Kocvalue = 1050)

Description of key information

In a study performed in OECD 121, Ferrocene was determined to have a log10Koc value of 3.0 (equivalent Koc value = 1050)

Key value for chemical safety assessment

Koc at 20 °C:
1 050

Additional information

In a study performed in OECD 121, Ferrocene was determined to have a log10Kocvalue of 3.0 (equivalent Kocvalue = 1050). (The log10Kocvalue determined by interpolation.)

[LogKoc: 3.0]