First-aid measures

General advice:
Remove contaminated clothing.
If inhaled:
Keep patient calm, remove to fresh air, seek medical attention.
On skin contact:
Wash thoroughly with soap and water.
On contact with eyes:
Wash affected eyes for at least 15 minutes under running water with eyelids held open. If irritation
develops, seek medical attention.
On ingestion:
Rinse mouth immediately and then drink plenty of water, seek medical attention.

Fire-fighting measures

Suitable extinguishing media:
water, dry extinguishing media, foam, carbon dioxide
Special protective equipment:
Wear a self-contained breathing apparatus.
Further information:
Collect contaminated extinguishing water separately, do not allow to reach sewage or effluent
systems.

Accidental release measures

Personal precautions:
Handle in accordance with good industrial hygiene and safety practice.
Environmental precautions:
Do not empty into drains.
Methods for cleaning up or taking up:
For large amounts: Pump off product.
For residues: Pick up with suitable absorbent material (e.g. sand, sawdust, general-purpose binder,
kieselguhr). Dispose of absorbed material in accordance with regulations.

Handling and storage

Handling
Ensure thorough ventilation of stores and work areas.
Protection against fire and explosion:
Prevent electrostatic charge - sources of ignition should be kept well clear - fire extinguishers should
be kept handy.
Storage
Segregate from acids and acid forming substances.
Further information on storage conditions: Keep container tightly closed in a cool, well-ventilated
place. Protect from the effects of light.
Storage stability:
Storage temperature: 25 °C
Storage duration: 12 Months
The product is stabilized, the shelf life should be noted.
From the data on storage duration in this safety data sheet no agreed statement regarding the
warrantee of application properties can be deduced.
additives:
potassium hydroxide (CAS Number: 1310-58-3)
Content: 0.01 %

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Personal protective equipment
Respiratory protection:
Wear respiratory protection if ventilation is inadequate. Gas filter for gases/vapours of organic
compounds (boiling point >65 °C, e. g. EN 14387 Type A)
Hand protection:
Chemical resistant protective gloves (EN 374)
Suitable materials also with prolonged, direct contact (Recommended: Protective index 6,
corresponding > 480 minutes of permeation time according to EN 374):
fluoroelastomer (FKM) - 0.7 mm coating thickness
Manufacturer's directions for use should be observed because of great diversity of types.
Supplementary note: The specifications are based on tests, literature data and information of glove
manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g.
temperature) it must be considered, that the practical usage of a chemical-protective glove in practice
may be much shorter than the permeation time determined through testing.
Eye protection:
Safety glasses
General safety and hygiene measures:
Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work
clothing is required additionally to the stated personal protection equipment. Do not inhale
gases/vapours/aerosols.

Stability and reactivity

Hazardous reactions:
Evolution of heat under influence of acids.

Disposal considerations

Incinerate in suitable incineration plant, observing local authority regulations.
A waste code in accordance with the European waste catalog (EWC) cannot be specified, due to
dependence on the usage.
The waste code in accordance with the European waste catalog (EWC) must be specified in
cooperation with disposal agency/manufacturer/authorities.
Contaminated packaging:
Contaminated packaging should be emptied as far as possible; then it can be passed on for recycling
after being thoroughly cleaned.