Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 November 2018
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187 “Particle Size Analysis by Laser Diffraction”
Version / remarks:
Handbook K, 2007
Deviations:
no
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of particle tested:
other: Sample tested as received

Test material

Constituent 1
Chemical structure
Reference substance name:
tetraethylammonium tetrafluoroborate
Cas Number:
429-06-1
Molecular formula:
C8H20BF4N
IUPAC Name:
tetraethylammonium tetrafluoroborate
Test material form:
solid: crystalline

Results and discussion

Mass median aerodynamic diameter:
807 - <= 825 µm
Geometric standard deviation:
1.407 - <= 1.436
Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
469 - <= 479 µm
St. dev.:
473
Key result
Percentile:
D50
Mean:
728 - <= 743 µm
St. dev.:
737
Key result
Percentile:
D90
Mean:
1 160 - <= 1 210 µm
St. dev.:
1 180

Any other information on results incl. tables

Using the identified parameters, the particle size was analysed over the range 0.01 µm to 3500 µm. The results of the formal analysis are following:

Applicant's summary and conclusion

Executive summary:

The laser diffraction test conducted to determine the particle size of Tetraethylammonium tetrafluoroborate, the results are summarised below. The analysis was conducted using the dry powder module.