Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: Particle Size Analysis
GLP compliance:
yes (incl. QA statement)
Remarks:
CHILWORTH
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Mean:
63.46 µm
Remarks on result:
other: 95% CI: 8 - 503 µm
Key result
Percentile:
D50
Mean:
62.43 µm
St. dev.:
2.88
Conclusions:
The mean particle size D50 was determined to 62.43 µm.

Description of key information

The mean particle size D50 was determined to 62.43 µm.

Additional information