Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-09-30 to 2010-12-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
31 May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN Manual Test Methods, 32.4.1; United nations 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Key result
Flash point:
81.5 °C
Atm. press.:
1 013 hPa
Conclusions:
The flash point of Incorez 397 was determined to 81.5 °C according to the Pensky Martens closed cup method.
Executive summary:

The determination of the flash point of Incorez 397 was performed according to EU Method A.9 and UN Manual of Test Methods, 32.4.1 (United Nations 2008). The test system used was a flash point tester according to Pensky-Martens using the equilibrium method with closed cup and electrical ignition. The flash point was internally corrected to standard pressure. The flash point was determined as 81.5 ± 1 °C. This value is the mean of two independent determinations.

Description of key information

The flash point of Incorez 397 was determined to 81.5 °C according to the Pensky Martens closed cup method.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
81.5 °C

Additional information

The determination of the flash point of Incorez 397 was performed according to EU Method A.9 / UN Manual of Test Methods, 32.4.1 (United Nations 2008). The test system used was a flash point tester according to Pensky-Martens using the equilibrium method with closed cup and electrical ignition. The flash point was internally corrected to standard pressure. The flash point was determined as 81.5 ± 1 °C. This value is the mean of two independent determinations.