This study has been performed inorder to determine the particle size distribution of CA 2343. This study was performed in accordance with ISO 13320 -1, which is based on the principle of light diffraction. 
The test substance was analysed in triplicate.The median of mass distribution (diameter) is 19.4 µm.
Size distribution:
Percent mass above 400 µm diameter:       0       %
Percent mass below 4 µm diameter:       7.0      %

Additional information

 

Guideline Test Type

Species

Median of mass distribution µm

 Reference

Reliability

 

ISO 13320-1

Not applicable

19.4

Füldner, H.H., Novartis, 1999