Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
additional toxicological information
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2009-03-16 - 2009-03-24

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Type of study / information:
Dust exposure during loading, storing and stock tranfer of urea based fertilizer treated with N-(2-Nitrophenyl)phosphoric triamide
Test guideline
Qualifier:
no guideline available
GLP compliance:
no

Results and discussion

Any other information on results incl. tables

Messstelle Nr.

Probe Nr.

Probenahmezeit

Probeluftvolumen

ermittelte Staubkonz.

Bemerkungen

[Uhr]

[m3]

[mg/m3]

1

Abwurfstelle LKW-Beladung

1

10:45-14:00

0,680

1,60

keine optisch wahrnehmbare Exposition

2

14:00- 15:40

0,350

1,95

leichte Exposition erkennbar

2

Abwurfstelle für die Einlagerung in die Boxen

1

10:17- 14:30

2,530

1,14

keine optisch wahrnehmbare Exposition

2

14:30-15:40

0,702

1,80

leichte Exposition erkennbar

3

Abwurf vom Band in Box 4

1

10:17-13:25

0,670

1,01

keine optisch wahrnehmbare Exposition

2

13:25-14:07

0,175

1,37

3

14:07-15:40

0,308

1,83

leichte Exposition erkennbar

Applicant's summary and conclusion

Conclusions:
The general dust limit value according to TRGS 900 is composed of the limit value for the alveolar fraction (3mg/m3) and the limit value for the respirable fraction (10 mg/m3). The measured dust exposure was estimated to be smaller than the limit values.
Executive summary: