Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019-2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
2009
Deviations:
no
Principles of method if other than guideline:
Not applicable.
GLP compliance:
yes (incl. QA statement)
Remarks:
Inspected on 15-16/11/2017, Signed on 15/05/2018
Type of method:
static method
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
516 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
670 Pa

Findings

Measurement Values

The measured values are presented in the following table.

Measurement Values, Date: 26. – 29.May 2020

1. Determination
increasing temperature

2. Determination
decreasing temperature

Temp. in °C

Time

Pressure in hPa

Temp. in °C

Time

Pressure in hPa

20.0

13:30

5.0

53.0

13:30

25.1

27.9

14:15

7.9

44.9

14:50

20.8

36.0

07:30

12.9

36.1

15:10

13.0

43.9

10:00

16.2

28.2

15:40

8.0

51.8

11:05

21.5

19.9

07:00

4.9

60.0

11:50

28.8

15.1

07:40

3.6

Results

The calculation results are presented in the following table:

Calculated values for 1/T and log P

n

Temperature T

Pressure p

Temperature T

1/T

log p

 

°C

hPa

K

1/K

log Pa

1

20.0

5.0

293.15

0.00341122

2.6990

2

27.9

7.9

301.05

0.00332171

2.8976

3

36.0

12.9

309.15

0.00323468

3.1106

4

43.9

16.2

317.05

0.00315408

3.2095

5

51.8

21.5

324.95

0.00307740

3.3324

6

60.0

28.8

333.15

0.00300165

3.4594

7

53.0

25.1

326.15

0.00306607

3.3997

8

44.9

20.8

318.05

0.00314416

3.3181

9

36.1

13.0

309.25

0.00323363

3.1139

10

28.2

8.0

301.35

0.00331840

2.9031

11

19.9

4.9

293.05

0.00341239

2.6902

12

15.1

3.6

288.25

0.00346921

2.5563

 

The parameters for the linear regression of the graph log (p) vs. 1/T are presented in the following table:

Linear Regression Parameters

Parameter

Value

Slope

-1978.720994

Intercept

9.462700901

Correlation coefficient r

-0.990557148

Coefficient of determination r2

0.981203463

 

Using the equation which is stated in chapter9, vapour pressures at ambient temperature were calculated as:

Calculated Values for vapour pressure

Parameter

Value

Unit

Vapour Pressure (20.0 °C)

516

Pa

Vapour Pressure (25.0 °C)

670

Pa

 

Conclusions:
The vapour pressure of the test item was calculated as 516 Pa at 20.0 °C and 670 Pa at 25.0 °C.
Executive summary:

An experimental study, conducted in accordance with conditions recommended in OECD guideline and under GLP, was performed. The vapour pressure was measured using the static method as described in EU method A.4.Twelve pairs temperature/vapour pressure were used to calculate a regression from which vapour pressure at ambient temperature could be estimated.

From the measured values, the vapour pressure of the test item was calculated as 516 Pa at 20.0 °C and 670 Pa at 25.0 °C. The values of the heating and cooling down phase showed good correspondence.

Therefore, the result of the study is considered valid.

Description of key information

The vapour pressure of the test item was calculated as 516 Pa at 20.0 °C and 670 Pa at 25.0 °C.

Key value for chemical safety assessment

Vapour pressure:
516 Pa
at the temperature of:
20 °C

Additional information

An experimental study, conducted in accordance with conditions recommended in OECD guideline and under GLP, is performed. It should be considered as a key study. The result should be retained as key data.