Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
Council Regulation (EC) No 440/2008 A.3
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: DIN 5175 in combination with DIN EN ISO 12185 'Crude petroleum and petroleum products -Determination of density- Oscillating U-tube Method'
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
oscillating densitimeter

Test material

Constituent 1
Chemical structure
Reference substance name:
N-(2-chloroethyl)-N-ethylaniline
EC Number:
245-082-0
EC Name:
N-(2-chloroethyl)-N-ethylaniline
Cas Number:
22564-43-8
Molecular formula:
C11H16ClN
IUPAC Name:
N-(2-chloroethyl)-N-ethylaniline

Results and discussion

Density
Key result
Type:
relative density
Density:
1.057
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The GLP study was performed according to EU method A.3 without deviations and therefore reliability of Klimisch 1 has been assigned. The relative density has been determined to be 1.057.
Executive summary:

The relative density of 1.057 of the test substance was determined in a GLP test according to EU method A.3 using the Oscillating U-tube Method. The U-tube of the measurement device was tempered at 20 °C and filled with the test item by a syringe. The result was taken, when the 2nd decimal place was stable. The measurement was repeated one time.