Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 March 2004 to 10 March 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
European Economic Community (EEC), EEC-Directive 92/69 EEC, Part A, Methods for the determination of physico-chemical properties, A.9 "Flash-point", EEC Publication No. L383, December. 1992.
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
DIN EN 22719: "Bestimmung des Flammpunktes Verfahren nach Pensky-Martens im geschlossenen Tiegel"; December 1993.
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
Not specified
Specific details on test material used for the study:
No further details specified in the study report.
Key result
Flash point:
251.5 °C
Atm. press.:
102.9 kPa

Preliminary test

Estimated flash-point for Hatcol 5127

Test substance

Estimated flash-point [°C]

Hatcol 5127

252

 

Main Study

Flash-point for Hatcol 5127

Test

Flash-point

[°C]

Lowest flash-point

[°C]

1

2

252

256

252

 

The lowest flash-point was corrected for the atmospheric pressure (i.e. 102.9 kPa).

Corrected flash-point = 252 + 0.25 (101.3-102.9) °C

                                   = 251.60 °C

Rounded off to 0.5 °C gives a flash-point for Hatcol 5127: 251.5 °C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash-point determined for Hatcol 5127, using a Pensky-Martens closed cup:
Hatcol 5127: 251.5 °C
Executive summary:

The determination of the flash-point was performed in accordance with EEC-Directive 92/69 EEC, A.9 "Flash-point" (1992) and DIN EN 22719: "Bestimmung des Flammpunktes Verfahren nach Pensky-Martens im geschlossenen Tiegel"; December 1993.

 

For the determination of the flash-point of Hatcol 5127 a Pensky-Martens closed cup flash-point apparatus was used. The results are summarized below.

 

Test substance

Flash-point [°C]

Hatcol 5127

251.5

 

Description of key information

 

Test substance

Flash-point [°C]

Hatcol 5127

251.5

 

Key value for chemical safety assessment

Flash point at 101 325 Pa:
251.5 °C

Additional information

For the determination of the flash-point of Hatcol 5127 a Pensky-Martens closed cup flash-point apparatus was used. The results are summarized below.

 

Test substance

Flash-point [°C]

Hatcol 5127

251.5