Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 23 October 2003 and 03 November 2003.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Sponsor's identification SBCAT-03
Description white powder
Batch number UK030622B
Date received 09 October 2003
Storage conditions room temperature in the dark

Data relating to the identity, purity and stability of the test material are the responsibility of the Sponsor.
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
0
Moisture (wt %):
0.1
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Moisture Content



































 



Determination A



Determination B



a) Mass of loss bottle (g)



18.2375



20.3426



b) Mass of loss bottle and test material (g)



19.2379



21.3430



c) Mass of loss bottle and test material


after drying (g)


 



19.2379



21.3431



Moisture content (% w/w)



<0.1



<0.1



Mean moisture content(% w/w)



<0.1


Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test material has been determined to be not highly flammable as it failed to ignite in the
preliminary screening test.
Executive summary:

Hazardous physico-chemical properties were determined using methods specified in Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).


Flammability (Solids), Method: A10, Result: Not highly flammable.

Description of key information

The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification