Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
yes
Remarks:
The heating rate slightly deviated from the value stated in the guideline of 0.5 °C/min (0.57 °C/min). This is considered as uncritical as a nominal heating rate of 0.5 °C/min was adjusted at the instrument and only a minimal deviation was ob-served.
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1,2,4-triazole-3-thiol
EC Number:
221-656-6
EC Name:
1,2,4-triazole-3-thiol
Cas Number:
3179-31-5
Molecular formula:
C2H3N3S
IUPAC Name:
4H-1,2,4-triazole-3-thiol
Test material form:
solid: crystalline

Results and discussion

Relative self-ignition temperature (solids)
Key result
Relative self-ignition temperature:
> 220 °C
Remarks on result:
no self ignition observed under the test conditions

Applicant's summary and conclusion

Conclusions:
No increase in the temperature of the sample in comparison to that of the oven could be detected; also no signs of ignition could be observed.
The test item 3-Mercapto-1,2,4-triazole is considered as showing no self-ignition up to the melting range of 218.5 – 220.0 °C under the test conditions
No observations were made which might cause doubts concerning the validity of the study outcome.
Executive summary:

The auto-flammability behaviour was determined by placing the test item into a stainless steel cube and heating from room temperature to an oven temperatureof 225 °C with the ZPA-3 oven.

No increase in the temperature of the sample in comparison to that of the oven could be detected, also no signs of ignition could be observed.

Therefore, the test item3-Mercapto-1,2,4-triazoleshould be considered as

 

showing no self-ignition up to the melting range of 218.5 – 220.0 °C