Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
Pensky-Martens flash point tester
Specific details on test material used for the study:
Batch no.: E 16734
Purity: 100%
Appearance: liquid to paste
Key result
Flash point:
178 °C
Atm. press.:
101.3 kPa

The main test was performed in duplicate. A clear flash point was observed at a temperature of 176°C and 177°C, respectively. The mean value was calculated to be 176.5°C at the actual atmospheric pressure of 97.1 kPa. After correction for the atmospheric pressure, the flash point of the test substance was determined to be 178°C at 101.3 kPa using the Pensky-Martens flash point apparatus.

Conclusions:
Under the study conditions, the flash point of the test substance was determined to be 178°C at 101.3 kPa (closed cup method).
Executive summary:

A study was conducted to determine the flash point of the test substance according to EU Method A.9 and ISO 2719 (Pensky-Martens closed cup method). In the preliminary test, a flash point of 180°C was found. Therefore (flash point above 65°C to be expected), the main study was performed using the Pensky-Martens flash point tester. The main test was performed in duplicate. A clear flash point was observed at a temperature of 176°C and 177°C, respectively. The mean value was calculated to be 176.5°C at the actual atmospheric pressure of 97.1 kPa. After correction for the atmospheric pressure, the flash point of the test substance was determined to be 178°C at 101.3 kPa. Under the study conditions, the flash point of the test substance was determined to be 178°C at 101.3 kPa (Tognucci, 1999).

Description of key information

The flash point was determined according to EU Method A.9 and ISO Method 2719 (Pensky-Martens closed cup method) (Tognucci, 1999)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
178 °C

Additional information