Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 4, 2007 - January 15, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Corsair Clear #12
- Substance type: Soft waxy beige solid
- Physical state: Solid
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Boiling point
Atm. press.:
101.325 kPa
Decomposition:
yes
Decomp. temp.:
ca. 150 °C
Remarks on result:
other: No boiling was observed below the decomposition temperature.

Applicant's summary and conclusion

Conclusions:
Reaction and/or decomposition of the test substance were observed above approximately 150°C (423K): boiling of Corsair Clear #12 was not observed below the temperature at which reaction and/or decomposition started. Therefore, the test substance has no boiling temperature.