Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 Jan 2018 - 17 Jan 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of particle tested:
agglomerate
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
N-(tri(hydroxymethyl)methyl)glycine
EC Number:
227-193-6
EC Name:
N-(tri(hydroxymethyl)methyl)glycine
Cas Number:
5704-04-1
Molecular formula:
C6H13NO5
IUPAC Name:
2-{[1,3-dihydroxy-2-(hydroxymethyl)propan-2-yl]amino}acetic acid
Test material form:
solid: particulate/powder

Results and discussion

Mass median aerodynamic diameter:
ca. 54.07 µm
Geometric standard deviation:
> 2.117 - < 2.135
Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
< 20.774 µm
St. dev.:
0.673
Key result
Percentile:
D50
Mean:
< 52.767 µm
St. dev.:
0.649
Key result
Percentile:
D90
Mean:
< 134.433 µm
St. dev.:
1.945

Any other information on results incl. tables

Using the identified parameters, the particle size was analyzed over the range 0.02 μm to 2000 μm.

The results of the formal analysis are presented in Table 9:1. In addition, a graph of volume (%) versus Particle Diameter (μm), and full particle size distribution, is provided in Graph 9.A (Average of 5 runs).

Table 9:1 : Full Test Results

 

RUN 1

RUN 2

RUN 3

RUN 4

RUN 5

Average**

Volume weighted mean

67.869

68.299

69.728

68.871

69.802

68.914

Median

53.225

53.304

53.305

52.208

51.763

52.767

Mode

53.01

52.318

52.293

51.052

50.098

51.774

MMAD *

54.539

54.62

54.622

53.498

53.041

54.07

d10 - 10 % of material is <

20.271

21.75

21.39

20.517

19.989

20.774

d50 - 50 % of material is <

53.225

53.304

53.305

52.208

51.763

52.767

d90 - 90 % of material is <

136.403

131.419

134.034

133.738

136.737

134.433

All results are in µm

* Mass median aerodynamic diameter

** Average result is calculated from the entirety of data captured in each run and is not a simple arithmetic mean.

1.26 % by volume of sample was seen to be < 10.00 µm.

Table 9:2 : Standard Deviation results

Run No.

1

2

3

4

5

STDVP

% STDVP

d10 - 10 % of material is <

20.271

21.75

21.39

20.517

19.989

0.673

3.2

d50 - 50 % of material is <

53.225

53.304

53.305

52.208

51.763

0.649

1.2

d90 - 90 % of material is <

136.403

131.419

134.034

133.738

136.737

1.945

1.4

d15.78 - 15.78 % of material is <

24.925

26.29

25.947

24.999

24.45

0.686

2.7

GSD

2.135

2.028

2.054

2.088

2.117

0.04

1.9

MMAD

54.539

54.62

54.622

53.498

53.041

0.665

1.2

GSD = Geometric standard deviation of the lognormal particle size distribution (calculated from d50/d15.78) STDVP = standard deviation of the population

% STDVP = percentage standard deviation of the population

Coefficient of variation for d50 is less than 3%; d10 and d90 are less than 5%. Thus repeatability of the characteristic particles in the size distribution are within the acceptable limits as per the ISO 13320-1 test standard.

Applicant's summary and conclusion

Conclusions:
The particle size was analysed over the range 0.02 µm to 2000 µm using a DPM Module. The average result is calculated from the entirety of data captured in each of the five runs. The averages are: d10 - 10 % of material is <20.774, d50 - 50 % of material is <52.767, and d90 - 90 % of material is <134.433.
Executive summary:

 The particle size was analysed over the range 0.02 µm to 2000 µm using a DPM Module. The average result is calculated from the entirety of data captured in each of the five runs. The averages are: d10 - 10 % of material is <20.774, d50 - 50 % of material is <52.767, and d90 - 90 % of material is <134.433.