Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

QSAR (Derek): No alerts in the Derek knowledge base were raised for skin sensitisation. Reliability = 2

QSAR (TIMES): The test substance is predicted to be a non-sensitizer. Reliability = 2

QSAR (TOPKAT): The test substance is predicted to be a non-sensitizer. Reliability = 2

Key value for chemical safety assessment

Skin sensitisation

Link to relevant study records

Referenceopen allclose all

Endpoint:
skin sensitisation, other
Remarks:
QSAR
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a (Q)SAR model, with limited documentation / justification, but validity of model and reliability of prediction considered adequate based on a generally acknowledged source
Qualifier:
no guideline followed
Principles of method if other than guideline:
Derek Nexus: 5.0.2, Nexus: 2.1.1
Derek prediction report is attached in IULCID.
GLP compliance:
no
Specific details on test material used for the study:
- Smiles: C(=O)(NCCCNC(=O)CCC=1C=C(C(C)(C)C)C(=C(C(C)(C)C)C=1)O)CCC2=CC(C(C)(C)C)=C(C(C(C)(C)C)=C2)O
Remarks on result:
no indication of skin sensitisation
Remarks:
No alerts in the Derek knowledge base were raised for organ toxicity
Conclusions:
No alerts in the Derek knowledge base were raised for skin sensitisation.
Executive summary:

The Derek model for skin sensitisation was used within the Nexus database. No alerts in the Derek knowledge base were raised for skin sensitisation.

Endpoint:
skin sensitisation, other
Remarks:
QSAR
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Qualifier:
no guideline followed
Principles of method if other than guideline:
Times v2.27.19.13
Toolbox prediction report is attached in IUCLID
GLP compliance:
no
Specific details on test material used for the study:
Smiles: CC(C)(C)c1cc(CCC(=O)NCCCNC(=O)CCc2cc(C(C)(C)C)c(O)c(C(C)(C)C)c2)cc(C(C)(C)C)c1O
Parameter:
other: QSAR skin sensitization model
Remarks on result:
no indication of skin sensitisation
Conclusions:
The test substance is predicted to be a non-sensitiser.
Executive summary:

The Times model for skin sensitisation was used. The test substance is predicted to be a non-sensitiser. Additional supporting documentation is provided in the prediction report attached in IUCLID.

Endpoint:
skin sensitisation, other
Remarks:
QSAR
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
Qualifier:
no guideline followed
Principles of method if other than guideline:
BIOVIA Discovery Studio v4.5
Prediction report is attached in IUCLID
GLP compliance:
no
Specific details on test material used for the study:
SMILES: CC(C)(C)c1cc(CCC(=O)NCCCNC(=O)CCc2cc(C(C)(C)C)c(O)c(C(C)(C)C)c2)cc(C(C)(C)C)c1O
Parameter:
other: QSAR skin sensitisation
Remarks on result:
no indication of skin sensitisation
Conclusions:
The test substance is predicted to be a non-sensitiser.
Executive summary:

The BIOVIA model for skin sensitisation was used. The test substance is predicted to be a non-sensitiser. Additional supporting documentation is provided in the prediction report attached in IUCLID.

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not sensitising)
Additional information:

The Times and TOPKAT models were used to determine the skin sensitisation potential of the test substance. The models indicate that the test substance is unlikely to be a skin sensitizer. Additionally, no alerts in the Derek knowledge base were raised for skin sensitisation.

 

Respiratory sensitisation

Endpoint conclusion
Endpoint conclusion:
no study available

Justification for classification or non-classification

Based on various QSAR models, the test substance is not expected to be a skin sensitizer, and no classification is required for skin sensitisation according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.