Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
2012-07-24 to 2012-09-05
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Human Skin Model Test)
Version / remarks:
2004-04-13
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1-Ethyl-3-methylimidazolium benzoate
EC Number:
695-723-7
Cas Number:
150999-33-0
Molecular formula:
C13H16N2O2
IUPAC Name:
1-Ethyl-3-methylimidazolium benzoate
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch No.of test material: 10361/11/203

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Justification for test system used:
Based on the results of ECVAM (European Center for Validation of Alternative Methods) funded validation studies, it was concluded by the ECVAM Scientific Advisory Committee that the EpiDerm™ human epidermis model is suitable to be used for distinguishing between corrosive and non-corrosive chemicals (ECVAM: ESAC statement on the application of the EpidermTM human skin model for skin corrosivity testing of 14-15 Mar 2000) as well as between irritant and non-irritant chemicals (ECVAM: ESAC statement on the scientific validity of in-vitro tests for skin irritation testing of 5 Nov 2008).
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: Epi-200, MatTek In Vitro Life Science Laboratories, Bratislava, Slovakia

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during exposure: 37 °C / room temperature
- Temperature of post-treatment incubation: 37 °C

REMOVAL OF TEST MATERIAL AND CONTROLS
- Washing steps: with PBS, 3 min or 1 h after start of exposure and after incubation.
- Observable damage in the tissue due to washing: No

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1.0 mg / mL
- Incubation time: 55 - 65 min
- Spectrophotometer: SunriseTM Absorbance Reader
- Wavelength: 570 nm without reference filter

NUMBER OF REPLICATE TISSUES: 2

NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 1

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if the viability after 3 minutes exposure is less than 50 %, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15 %.
- The test substance is considered to be non-corrosive to skin if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is greater than or equal to 15 %.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount applied: 50 µL

NEGATIVE CONTROL
- Amount applied: 50 µL

POSITIVE CONTROL
- Amount applied: 50 µL
- Concentration: 8-n potassium hydroxide solution
Duration of treatment / exposure:
3 min or 1 h
Duration of post-treatment incubation (if applicable):
3 h
Number of replicates:
2

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 min exposure
Value:
107
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
1 h exposure
Value:
45
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: Yes
- Acceptance criteria met for positive control: Yes
- Acceptance criteria met for variability between replicate measurements: The value for inter-tissue variability of the test substance for the exposure period of 1 hour is about 0.34 and therefore out of the acceptance range. Since all other quality criteria of the test were met and the viability values of both tissues are well above the cut off for skin corrosion, this deviation is not considered to adversely affect the result of this study.

Any other information on results incl. tables

 

 

Exposure: 3 min

Exposure: 1 hour

Test substance

 

Tissue 1

Tissue 2

Mean

Tissue 1

Tissue 2

Mean

NC

Mean OD570

2.109

2.079

2.094

2.113

2.154

2.134

Viability
[% of NC]

100.7

99.3

100

99.0

101.0

100

Test substance

Mean OD570

2.239

2.249

2.244

1.124

0.785

0.954

Viability
[% of NC]

106.9

107.4

107

52.7

36.8

45

PC

Mean OD570

0.486

0.382

0.434

0.047

0.038

0.042

Viability
[% of NC]

23.2

18.3

21

2.2

1.8

2

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met