Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
1977
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1977
Report date:
1977

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Anthra[2,1,9-mna]naphth[2,3-h]acridine-5,10,15(16H)-trione
EC Number:
221-897-7
EC Name:
Anthra[2,1,9-mna]naphth[2,3-h]acridine-5,10,15(16H)-trione
Cas Number:
3271-76-9
Molecular formula:
C31H15NO3
IUPAC Name:
anthra[2,1,9-mna]naphth[2,3-h]acridine-5,10,15(16H)-trione
Test material form:
solid
Details on test material:
Vat Green 3

Sampling and analysis

Analytical monitoring:
no

Test solutions

Vehicle:
no

Test organisms

Test organisms (species):
activated sludge
Details on inoculum:
suspension of filtrate

Study design

Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
3 h

Test conditions

Reference substance (positive control):
no

Results and discussion

Effect concentrations
Key result
Duration:
3 h
Dose descriptor:
IC0
Effect conc.:
>= 156 mg/L
Nominal / measured:
nominal
Conc. based on:
act. ingr.
Basis for effect:
inhibition of heterotrophic respiration

Applicant's summary and conclusion

Validity criteria fulfilled:
not specified
Conclusions:
The 3-h IC0 to activated sludge respiration was determined at ca. 300 mg/L (corresponding to 156 mg/L act. ingr.). The substance is not toxic to bacteria and activated sludge.