Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-06-29 to 2016-07-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
Version / remarks:
28 July 2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
Version / remarks:
06 July 2012
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
N-carbamoylmethyliminodi(acetic acid)
EC Number:
247-530-0
EC Name:
N-carbamoylmethyliminodi(acetic acid)
Cas Number:
26239-55-4
Molecular formula:
C6H10N2O5
IUPAC Name:
2,2'-[(2-amino-2-oxoethyl)imino]diacetic acid
Test material form:
liquid

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Cell source:
other: Adult donors, not further detailed.
Justification for test system used:
The EPISKIN model has been validated for irritation testing in an international trial. After a review of scientific reports and peer reviewed publications on the EPISKIN method, it showed evidence of being a reliable and relevant stand-alone test for predicting rabbit skin irritation, when the endpoint is evaluated by MTT reduction and for being used as a replacement for the Draize Skin Irritation test (OECD TG 404 and Method B.4 of Annex V to Directive 67/548/EEC) for the purposes of distinguishing between skin irritating and no- skin irritating test substances (STATEMENT OF VALIDITY OF IN-VITRO TESTS FOR SKIN IRRITATION; ECVAM; Institute for Health & Consumer Protection; Joint Research Centre; European Commission; Ispra; 27 April 2007).
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiSkinTM Small Model (EpiSkinTM SM), manufactured by EPISKIN SNC Lyon, France
- Tissue batch number: 16-EKIN-026
- Production date: not specified
- Shipping date: not specified
- Delivery date: not specified
- Expiry date: 04 July 2016
- Date of initiation of testing: 2016-06-29

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: room temperature
- Temperature of post-treatment incubation: 37 °C

REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: 1 step using 25 mL PBS 1x solution
- Observable damage in the tissue due to washing: no
- Modifications to validated SOP: no

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 2 mL of 0.3 mg/mL MTT per well
- Incubation time: 3 hours (± 5 min)
- Spectrophotometer: 96-well plate spectrophotometer
- Wavelength: 570 nm
- Filter: not specified
- Filter bandwidth: not specified
- Linear OD range of spectrophotometer: not specified

FUNCTIONAL MODEL CONDITIONS WITH REFERENCE TO HISTORICAL DATA
- Histology scoring: Historical control value: >= 19.5, 22.7 +/- 0.5 for batch used
- IC50: Historical control value: 1.5 mg/mL <= IC50 <= 3 mg/mL, 2.6 mg/mL for batch used
- Morphology: Well-differentiated epidermis consisting of a basal layer, several spnous and granular layers and a thick stratum corneum was satisfactory in the batch used.
- Contamination: Blood of donor: absence of HIV 1+2, hepatitis C anitbodies and hepatitis B antigen HB; epidermal cells of donor: absence of bacteria, fungus and mycoplasma

NUMBER OF REPLICATE TISSUES: 3

CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
The test material did not interact with the MTT, therefore additional controls and data calculations were not necessary.

NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 1

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive or irritating to skin if the viability after exposure is <= 50 %.
- The test substance is considered to be non-corrosive to skin if the viability after exposure is greater than 50 %.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount applied: 10 mg (to moistened skin)

NEGATIVE CONTROL
- Amount applied: 10 µL

POSITIVE CONTROL
- Amount applied: 10 µL
- Concentration: 5 % aq.
Duration of treatment / exposure:
15 minutes (± 0.5 min)
Duration of post-treatment incubation (if applicable):
42 hours (± 1h)
Number of replicates:
3

Results and discussion

In vitro

Results
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
1
Value:
91
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Remarks:
100 %
Positive controls validity:
valid
Remarks:
18 %
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: none
- Direct-MTT reduction: no
- Colour interference with MTT: no

DEMONSTRATION OF TECHNICAL PROFICIENCY: Prior to routine use of the method the laboratory demonstrated the technical proficiency in a separate study using the ten Proficiency Chemicals according to OECD Test Guideline No. 439.

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: YES (mean OD of 0.762 in the range from 0.6 to 1.5; SD of 10.23 < 18)
- Acceptance criteria met for positive control: YES (mean viability of 18 % in the range from 0 to 40 %; SD of 7.55 < 18)
- Acceptance criteria met for variability between replicate measurements: YES (test substance: SD of 7.11 < 18)
- Range of historical values if different from the ones specified in the test guideline: no

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item is considered to be non-irritant to skin.
Executive summary:

An EpiSkinTM SM test with the test item has been performed to predict its irritation potential by measurement of its cytotoxic effect, as reflected in the MTT assay, according to the OECD Test Guideline No. 439, 28 July 2015. Triplicates of the human skin model EPISKIN (Reconstructed Human Epidermis, SkinEthic Laboratories) were treated with test item and incubated for 15 minutes at room temperature. Exposure of the reconstructed human epidermis skin units with test item was terminated by rinsing with PBS 1x solution. Epidermis units were then incubated at 37 °C for 42 hours in an incubator with 5 % CO2. The viability of each disk was assessed by incubating the tissues for 3 hours with MTT solution at 37 °C in 5 % CO2 protected from light. The precipitated formazan was then extracted using acidified isopropanol and quantified spectrophotometrically. SDS (5 % aq.) and 1×PBS treated epidermis (three units / positive and negative control) were used as positive and negative controls respectively. For each treated tissue viability was expressed as a percentage relative to negative control. In this in vitro skin irritation test using the EPISKIN model, the test item did not show significantly reduced cell viability in comparison to the negative control (mean value: 91 %). All obtained test item viability results were far above 50 % when compared to the viability values obtained from the negative control. Therefore the test item was considered to be non-irritant to skin. Positive and negative controls showed the expected cell viability values within acceptable limits. The experiment was considered to be valid. The results obtained from this in vitro skin irritation test, using the EPISKIN model, indicated that the test item reveals no skin irritation potential under the utilised testing conditions. The test item is considered to be non-irritant to skin.