Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Adequacy of study:
supporting study
Study period:
1990
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other:
Remarks:
Documentation insufficient for assessment
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
Test condition: Cleveland open cup
GLP compliance:
not specified
Type of method:
open cup
Flash point:
104 °C

Not applicable

Conclusions:
Flash point = 104 ºC
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Experimental measurement according to standardized method
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point:
99 °C
Atm. press.:
101.3 kPa

Reported flash point is average of four closed-cup determinations for the same substance using the same method, with values ranging from 96 - 101.5 °C

Endpoint:
flash point
Adequacy of study:
supporting study
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
88 °C
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2004
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data from handbook or collection of data
Justification for data waiving:
other:
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study
Principles of method if other than guideline:
Not applicable
GLP compliance:
not specified
Type of method:
open cup
Flash point:
93 °C

Not applicable

Conclusions:
Flash point = 93 ºC
Executive summary:

Not applicable

Description of key information

The closed-cup flash point of the substance has been determined to be 99 degrees Celcius (372 Kelvin).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
372 K

Additional information

Reported flash point represents average of four closed-cup determinations according to ASTM D93 -07. Because the flash point falls above 93 °C, the substance is not classified as a flammable liquid.