Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove exposed person to fresh air. If not breathing give
artificial respiration. If breathing is difficult administer
oxygen. Get medical attention.
Emergency measure - Eyes: Hold eyelides apart and flush with running water for atleast
15 minutes. Get medical attention if signs of irriation
develop.
Emergency measure - Skin: Remove contamined clothing. Wash with plenty of water for 15
minutes.
Emergency measure - Ingestion: Induction of vomiting should not to be necessary. Get
medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, carbon dioxide, foam or dry chemical.

Product arising from burning: Oxides of carbon, nitrogen and HCl.

Product determined by test: N

Protective equipment: SCBA, flame and chemical resistant clothing, boots and
gloves

Accidental release measures

Emergency measures in case of spillage: Wear full protective clothing: overalls, rubber boots,
gloves, eye protection and respirator when cleaning up a
spill. Collect material to minimize dust generation; use wet
mop, damp sponge or wet/dry HEPA vacuum. Place collected
material into a suitable container for disposal. After clean
up is complete, flush with water to process sewer under
national, state or local permits or regulations.

Handling and storage

Handling: Engineering controls in the form of local exhaust
ventilation are provided at the reactor. When engineering
controls are not sufficient to control dust approved
respirator protection in conformance with EN 136 standard
should be worn. For manufacturing areas, skin protection
should be provided in the form of overalls, or full air
suits along with impermeable gloves. Rubber, neoprene or
other gloves may be required if solvents, corrosives or
other chemicals are present. Chemical safety glasses should
be worn if a full-face respirator is not worn.

Storage: Room temperature acceptable. Maintain low humidity to avoid
clumping.

Packaging of the substance and or preparation: UN approved fibre drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: Not regulated for shipping.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Avoid sparks, heat and/or open flame

Chemical reaction with water: None

Dust explosion: Material exhibits relatively weak to moderate explosion
characteristics if ignited as a dust cloud. Material is
moderately susceptible to accumulating static during
processing and uncontrolled static discharge may result in
igniting a dust cloud under certain conditions. Provide
appropriate bonding and grounding protection to control
static charges. Powder handling equipment such as dust
collectors, dryers and mills may require additional
protective measures (explosion venting).

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: None

Industry - Possibility of neutralisation: None

Industry - Possibility of destruction: controlled discharge: All liquid wastes generated during the process are treated
following local authorities requirements.

Industry - Possibility of destruction - incineration: Incineration is recommended for large quantities. A
closed-cycle incinerator with scrubbers should be used.
National and local regulations must be observed. Code A663.

Industry - Possibility of destruction - water purification: Trace quantities can be destroyed by biological oxidation in
a waste treatment plant. National and local regulation must
be observed. Code A 641.

Public at large - Possibility of recovery/recycling: Not intended for public use.