Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 92/69/EEC, A4 (Dynamic method)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0.043 Pa
Remarks on result:
other: First vapour pressure
Temp.:
50 °C
Vapour pressure:
0.82 Pa
Remarks on result:
other: Second vapour pressure

Applicant's summary and conclusion