Administrative data

Endpoint:
additional physico-chemical information
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
The test was performend on the basis of mentioned guidelines with minor modifications. The test was conducted by well experienced staff of a safatey laboratory that routinely conducts this type of testing. Protocols for testing procedure are in place.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Literatur
a) BG Chemie, Anlagensicherheit, Sicherheitstechnische Kenngrößen, Ermitteln und
Bewerten, Merkblatt R 003, BGI 747, Heidelberg, 6/2000, S. 57
b) DIN 51412-1Prüfung von Mineralölerzeugnissen, Bestimmung der elektrischen Leitfähigkeit,
Laborverfahren, 8/1979
c) BG Chemie, Statische Elektrizität, Richtlinie für die Vermeidung von Zündgefahren
infolge elektrostatischer Aufladungen, Richtlinie Nr. 4, ZH 1/200, 10/1989
d) BG Chemie, Berufsgenossenschaftliche Regeln für Sicherheit und Gesundheit bei
der Arbeit, Vermeidung von Zündgefahren infolge elektrostatischer Aufladungen,
BGR 132, 3/2003
e) H. Steen (Hrsg.), Handbuch des Explosionsschutzes, Wiley-VCH Verlag GmbH,
Weinheim, 2000, S. 144-164
GLP compliance:
no
Endpoint investigated:
other: Electric conductivity

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
not specified
Details on test material:
Diethylphosphonoessigsäure
Molecular Weight = 196,14
Molecular Formula = C6H13O5P

Results and discussion

Results:
Electric conductivity = 1.3 x 10(-4) S/m at 23°C

Applicant's summary and conclusion

Conclusions:
genügend elektrisch leitfähig