Emergency measure - Inhalation: Using appropriate personal protective equipment, move
exposed subject to fresh air. If breathing is difficult or
ceases, ensure and maintain ventilation. Give oxygen as
appropriate. The exposed subject should be kept warm and at
rest. Obtain medical attention in cases of known or possible
over exposure, or with symptoms including chest
pain,difficulty breathing, loss of consciousness or other
adverse effects, which may be delayed.
Emergency measure - Eyes: Wash immediately with clean and gently flowing water.
Continue for at least 15 minutes. Obtain medical attention.
Emergency measure - Skin: Using appropriate personal protective equipment, remove
contaminated clothing and flush exposed area with large
amounts of water. Obtain medical attention if skin reaction
occurs, which may be immediate or delayed.
Emergency measure - Ingestion: Never attempt to induce vomiting. Do not attempt to give any
solid or liquid by mouth if the exposed subject is
unconscious or semi-conscious. Wash out the mouth with
water. Obtain medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, dry powder or foam extinguishers are recommended.
Carbon dioxide extinguishers may be ineffective.

Product arising from burning: The substance is combustible and will burn if involved in
a fire, evolving noxious fumes (eg carbon oxides).


Toxic, corrosive or flammable thermal decomposition products
are expected when the material is exposed to fire.

Product determined by test: N

Protective equipment: Since toxic, corrosive or flammable vapours might be evolved
from fires involving this material, self-contained
breathing apparatus and full protective equipment are
recommended for firefighters.


Move containers from the fire area if possible without
increased personal risk.


If possible, contain and collect firefighting water for
later disposal.


Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Fence or cordon the affected area and do not allow
individuals to touch or walk through the spilled material
unless wearing appropriate protective clothing.


Avoid dust formation.


Prevent entry into waterways, sewers, surface drainage
systems and poorly ventilated areas. If spill is outdoors,
cover with plastic sheet to minimise spreading or contact
with rain.


For clean-up collect and place it in a suitable, properly
labelled container for recovery or disposal. After all solid
or absorbent material has been collected, the area should
be vacuumed with HEPA filter-equipped apparatus.


No specific decontamination or detoxification procedures
have been identified for this material. Consider use of
water, detergent solutions, or other soluble solvents, for
clean-up and decontamination operations.


Dispose of waste material in accordance with local
regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.



Avoid dispersion as a dust cloud.


Depending upon the scale of the operation, use of
appropriate exhaust ventilation is recommended to provide
routine control of fire and explosion hazards during
handling of this material.


Ignition Controls: Bond and earth (ground) all plant

and equipment to ensure that no isolated conductors are
present. Isolated conductors can accumulate sufficient
electrostatic charge to produce discharges of many hundreds
of milli-Joules.

Storage: Keep in tightly closed containers or packages away from
moisture and away from sources of ignition.


Avoid prolonged storage at elevated temperatures (greater
than room temperature, approximately 20 degrees C).

Packaging of the substance and or preparation: 50 litre containers.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: None.
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.


A SDS should accompany all shipments for reference in the
event of spillage or accidental release. Only authorised
persons trained and competent in accordance with appropriate
national and international regulatory requirements may
prepare dangerous goods for transport.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Avoid direct sunlight, conditions that might generate heat
and dispersion as a dust cloud.

Chemical reaction with water: None which is hazardous.

Dust explosion: Under normal conditions of use this material does not
present a significant explosion hazard. However, like most
organic compounds it is combustible and may form a dust
explosion if widely dispersed in air.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration. In principle, it may be
possible to recover larger spillages of uncontaminated
material for subsequent use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is not
provisionally classified at this level of notification.



No chemical treatment is practicable to neutralise the
hazardous health properties.


The dust hazard will be minimised by good industrial hygiene
and the use of appropriate PPE and LEV.

Industry - Possibility of destruction: controlled discharge: None recommended.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes (eg. carbon
oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly
tothe sewage system or the aqueous environment.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: None.