Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Irrigate immediately with eyewash solution or clean water,
holding the eyelids apart, for at least 10 minutes. Seek
medical attention.
Emergency measure - Skin: Wash with water.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water spray, foam, dry powder or carbon dioxide may be used.

Product arising from burning: Products of combustion may contain oxides of carbon together
with hydrogen fluoride and soot.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus and suitable protective
clothing should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing (see 2.3.1).

Clear up spillages. Transfer to labelled containers for
disposal at a landfill site or by incineration in accordance
with local regulations. Wash the spillage area with water.

Do not allow to enter drains, sewers or water courses.

Handling and storage

Handling: Observe the usual precautions for handling organic
chemicals. Avoid contact with skin and eyes. Wear suitable
protective clothing.

Storage: Store in tightly closed containers in a cool, dry place.

Packaging of the substance and or preparation: 25 kg plastic full opening drum.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion: The material can form flammable dust clouds in air.

Group A dust.

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: The substance is acidic by nature and as such may be
effectively neutralised by the addition of dilute alkali.
(A632)

Industry - Possibility of destruction: controlled discharge: Disposal at an authorised landfill site is possible.

Discharge to water is not recommended.

(A650)

Industry - Possibility of destruction - incineration: Recommended method at an approved facility equipped with
waste gas treatment to remove hydrogen fluoride gas. The
incineration temperature must be at least 1100 deg C. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.