Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
no
Type of method:
effusion method: Knudsen cell

Test material

Constituent 1
Chemical structure
Reference substance name:
ethyl (2S)-3-[3,5-diamino-4-(4-methoxyphenoxy)phenyl]-2-acetamidopropanoate
Cas Number:
440667-78-7
Molecular formula:
C20H25N3O5
IUPAC Name:
ethyl (2S)-3-[3,5-diamino-4-(4-methoxyphenoxy)phenyl]-2-acetamidopropanoate
Test material form:
solid: particulate/powder

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#9
Temp.:
150 °C
Vapour pressure:
0.07 Pa
Key result
Test no.:
#8
Temp.:
135 °C
Vapour pressure:
0.024 Pa
Key result
Test no.:
#7
Temp.:
120 °C
Vapour pressure:
0.004 Pa

Applicant's summary and conclusion

Conclusions:
For the test substance L-Tyrosine, N-acetyl-3,5-diamino-O-(4-methoxyphenyl)-, ethyl ester, the following vapour pressures at 20 °C and at 25 °C were calculated from the regression equation:
Vapour pressure at 20 °C: 4.35 * 10-09 Pa
Vapour pressure at 25 °C: 1.08 * 10-08 Pa
The linear regression of log p vs. 1/T gave a correlation coefficient r of - 0.9934, showing good repeatability and precision. Therefore, the determination is considered as valid.