Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 8 December 2016 and 13 July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study is considered to be a reliability 1 as it has been conducted according to EU Method A.9 (Flash-Point) using the equilibrium closed cup method and in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Identification: FRET 11-0078
Appearance/Physical state: Clear colorless liquid
Storage conditions: Approximately 4 °C in the dark
Flash point:
104 °C
Atm. press.:
101.6 Pa

Results of the flash point determination are shown in the following table.

Test temperature (ºC)

Observations

21.0

No flash.

26.0

No flash.

31.0

No flash.

36.0

No flash.

41.0

No flash.

46.0

No flash.

51.0

No flash.

56.0

No flash.

61.0

No flash.

66.0

No flash.

71.0

No flash.

71.0 (fresh sample)

No flash.

76.0

No flash.

81.0

No flash.

86.0

No flash.

91.0

No flash.

96.0

No flash.

101.0 (fresh sample)

No flash.

106.0

A blue flash spread across the sample cup.

106.0 (fresh sample)

A blue flash spread across the sample cup.

101.0 (fresh sample)

No flash.

102.0 (fresh sample)

No flash.

103.0 (fresh sample)

No flash.

104.0 (fresh sample)

A blue flash spread across the sample cup.

104.0 (fresh sample)

A blue flash spread across the sample cup.

102.0 (fresh sample)

No flash.

Atmospheric pressure: 101.6 kPa

Corrected flash point: 103.9 ºC

Interpretation of results:
GHS criteria not met
Conclusions:
The Flash point of FRET 11-0078 was determined using an reliable GLP study according to EU Method A.9 (Flash-Point) using the closed cup equilibrium method . The Flash point of the substance is 104°C ± 2 °C at atmospheric pressure (101.6 kPa).

Executive summary:

The Flash point of FRET 11-0078 at atmospheric pressure (101.6 kPa), is 104°C ± 2 °C according to EU Method A.9 (Flash-Point) using the closed cup equilibrium method.

Description of key information

The Flash point of FRET 11 -0078 at atmospheric pressure (101.6 kPa), is 104°C ± 2 °C according to EU Method A.9 (Flash-Point) using the closed cup equilibrium method.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104 °C

Additional information