Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013-07-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
effusion method: Knudsen cell
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0 Pa
Key result
Test no.:
#3
Temp.:
125 °C
Vapour pressure:
0 Pa

The vapour pressure was measured twice. The first measurement was performed in the temperature range of 115 °C to 140 °C.

  

Temperature / °C

Vapour pressure / hPa

115

2.2E-5

120

3.2E-5

125

3.8E-5

130

9.9E-5

135

1.5E-4

140

2.7E-4

 

 

Antoine parameters and extrapolated vapour pressures 

T / ° C

p / hPa

log (p/hPa) = A + B/(C+T[°C])

20

1.7E-11

A = 13.83698

25

4.54E-11

B = -7209.22

50

3.37E-9

C = 273.15

The values for 20, 25 and 50 °C are calculated, using the Antoine constants A, B and C

 

  

Conclusions:
The vapour pressure at 20, 25 and 50 °C was determined to be 1.76E-9, 4.54E-9 and 3.37E-7 Pa, respectively.
Executive summary:

A study was conducted according to OECD TG 104 and Regulation (EC) No 440/2008 method A.4 to determine the vapour pressure of the test item. The vapour pressure of the test item was determined at different temperatures (115 - 140 °C) using the effusion method (weight loss). The vapour pressure was calculated using the linear regression equation of the Log P versus 1/T function. The values for 20, 25 and 50 °C were calculated using the Antoine equation. The vapour pressure at 20, 25 and 50 °C was determined to be 1.76E-9, 4.54E-9 and 3.37E-7 Pa, respectively.

Description of key information

The vapour pressure at 20, 25 and 50 °C was determined to be 1.76E-9, 4.54E-9 and 3.37E-7 Pa, respectively.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

A study was conducted according to OECD TG 104 and Regulation (EC) No 440/2008 method A.4 to determine the vapour pressure of the test item. The vapour pressure of the test item was determined at different temperatures (115 - 140 °C) using the effusion method (weight loss). The vapour pressure was calculated using the linear regression equation of the Log P versus 1/T function. The values for 20, 25 and 50 °C were calculated using the Antoine equation.The vapour pressure at 20, 25 and 50 °C was determined to be 1.76E-9, 4.54E-9 and 3.37E-7 Pa, respectively.