Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 500 °C
Atm. press.:
101.8 kPa

Any other information on results incl. tables

Injection No.

Injection volume

of the sample

100 μL

150 μL

200 μL

 

Whether any cool-flame occurred

No

No

No

3

Test temperature ()

500

500

500

 

Whether any hot-flame occurred

 in 10 min 

No

No

No

 

Delay time (s)

/

/

/

 

Hot-flame temperature ()

/

/

/

Applicant's summary and conclusion

Conclusions:
>500°C (101.8 kPa)