Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06 June 2012 - 06 June 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
no guideline followed
Principles of method if other than guideline:
Principle:
-Powder density (and volume) is determined by the use of a fully-automatic gas displacement pycnometer.

Method:
Tare the empty sample cup
- Fill the sample cup to at least 2/3 of the cup capacity with sample and record the weight
- Insert the filled sample cup into the cell chamber and close the cell chamber
- Start the analysis

Apparatus:
- Gas pycnometer from Micromeritics AccuPyc 1330, Model: 133/34010/00, S/N: 3814
- Helium gas cylinder from Air Liquide (Alphagaz 1 quality), purity 99.999%
- Analytical balance with reading accuracy of at least ±0.1mg from Mettler Toledo, Model AE2005, S/N: J62549
GLP compliance:
not specified
Type of method:
pycnometer method
Specific details on test material used for the study:
Product code: 0245F
Product batch / lot: 280PE310516
Key result
Type:
relative density
Density:
2.257 g/cm³
Temp.:
27.4 °C

Sample weight: 1.9833 g

Temperature: 27.4°C

Number of Purges: 10

Cell Volume: 12.1224 cm^3

Equilibrium Rate: 0.1000 psi g / min

Expansion Volume: 9.3330 cm^3

Conclusions:
Powder density (and volume) is determined by the use of a fully-automatic gas displacement
pycnometer. Average Density of seven measurements was 2.2575 g/cm^3 ± 0.0014 g/cm^3.

Description of key information

Key value for chemical safety assessment

Relative density at 20C:
2.257

Additional information