Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08.October 2018 - 10.October 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Reference substance name:
Plum, ext.
EC Number:
290-179-3
EC Name:
Plum, ext.
Cas Number:
90082-87-4
Molecular formula:
not applicable
IUPAC Name:
Extract obtained from fruits of Prunus domestica L. Rosaceae
Test material form:
liquid
Details on test material:
- Physical appearance: Blackish brown to dark brown liquid
- Storage conditions: At room temperature
Specific details on test material used for the study:
Name (as stated in the report): Plum Concentrate A-270
Batch: DU00645869
Expiration date: April 19, 2019

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Key result
Type:
log Pow
Partition coefficient:
<= 1.1
Temp.:
25 °C
pH:
7

Applicant's summary and conclusion

Executive summary:

The Partition Coefficient n-octanol/water of Vetynal Extra was determined by the Reverse Phase High Performance Liquid Chromatographic Method according to the OECD Guidelines for Testing of Chemicals, Method No. 117.

 

The result is:

Partition coefficients n-octanol/water of Plum concentrate A-270 is     

 

log Pow<= 1.1*

                

 *peak outside the calibration domain