Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 1992 - January 1993
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well conducted study according to GLP
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report date:
1993

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
The following was measured:
- flash point (closed): according to BS6664 part 5 (Pensky-Martens closed cup)
- flash point (open) and fire point: according to BS2000 (Pensky-Martens open tester)
GLP compliance:
yes
Type of method:
other: see below

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Batch no 910312

Results and discussion

Flash pointopen allclose all
Flash point:
> 360 °C
Atm. press.:
771.1 mm Hg
Remarks on result:
other: closed
Flash point:
257 °C
Atm. press.:
771.1 mm Hg
Remarks on result:
other: open
Flash point:
284 °C
Atm. press.:
771.1 mm Hg
Remarks on result:
other: fire point

Applicant's summary and conclusion