Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (b) (i): BAM friction apparatus
Parameter:
limiting load (N)
Value:
360
Result:
negative, no explosion
Remarks on result:
limiting load > 360 N
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
limiting impact energy (J)
Value:
40
Result:
negative, no explosion
Remarks on result:
limiting impact energy > 40 J
Key result
Test series:
other: thermal sensitivity
Method:
other: Koenen steel tube apparatus
Parameter:
limiting diameter (mm)
Value:
6
Result:
negative, no explosion
Remarks on result:
other: No explosions were observed using the 6 mm or 2 mm orifice plates.
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance is not classified as explosive
Executive summary:

The study was conducted according guideline EC Test method A14. The study was conducted to determine explosive properties of test substance using BAM Friction apparatus (Friction sensitivity), BAM Fallhammer apparatus (Mechanical sensitivity) and Koenen steel tube apparatus (Thermal sensitivity). The test substance did not give a positive result in tests used to determine its sensitivity to friction, shock or heating under confinement, and is therefore not classified as an explosive

Description of key information

EU Method A.14

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

The test substance was not found to be sensitive to thermal, impact, or friction stimuli. Therefore, the test substance is not considered explosive and is not classified according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.