Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 Feb - 1 Mar 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Qualifier:
according to guideline
Guideline:
other: EU Method A.24 Partitition coefficient n-octanol/water
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
Phthalide
EC Number:
201-744-0
EC Name:
Phthalide
Cas Number:
87-41-2
Molecular formula:
C8H6O2
IUPAC Name:
1,3-dihydro-2-benzofuran-1-one

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Key result
Type:
log Pow
Partition coefficient:
0.5
Remarks on result:
other: The test was performed at room temperature.

Any other information on results incl. tables

The sample was tested as received. No further preliminary treatment such as drying or milling was performed. The results given in this report only apply to the tested sample.


The program KOWWIN (part of EPI Suite) was used for calculating the log Pow of the test item. The calculated value was 0.7.


Therefore, according to the guidelines the partition coefficient n-octanol/water of the test item at room temperature was determined by the HPLC method. The shake flask method was not applicable due to the low water solubility.


 


log Pow of the test item -1 st injection


 




















Test item



tR / min



k



log k



log Pw0



3H-2-benzofuran-1-one (Phthalide}



1.41



0.15



-0.83



0.6



 


log Pow of the test item - 2nd injection


 




















Test item



tR / min



k



log k



log Pow



3H-2-benzofuran-1-one (Phthalide)



1.41



0.15



-0.83



0.5



The partition coefficient Pow of the test item was determined to be:


log Pow= 0.5

Applicant's summary and conclusion

Executive summary:

The log Pow of the test substance was 0.5.