Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15.08. - 18.08.16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to EU and OECD guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0 hPa
Temp.:
25 °C
Vapour pressure:
0 hPa
Temp.:
50 °C
Vapour pressure:
0 hPa

Applicant's summary and conclusion

Executive summary:

The test item has a vapour pressure of 1.1*10 -8 hPa at 25°C.