Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: none flammable
Remarks:
The test did not ignite but melted only in 10 cm within 2 min when hot flame from gas burner (diameter of the burner, 25mm) was applied to one end of the powder train. There was no smoldering observed within four minutes of total testing period after the withdrawal of flame.

Applicant's summary and conclusion