Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08.-09.10.2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
no
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Key result
Temp.:
20 °C
Vapour pressure:
0 Pa
Key result
Temp.:
25 °C
Vapour pressure:
0 Pa
Key result
Temp.:
50 °C
Vapour pressure:
0 Pa

Applicant's summary and conclusion

Executive summary:

The vapour pressure of the test substance was 0.000013 Pa at 20°C, 0.000021 Pa at 25°C, and 0.00043 Pa at 50°C.