Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 November, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted according to an internationally recognised method, and under GLP. No deviation was reported. Test substance is adequately specified. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
Commission Regulation (EC) No 761/2009 of 23. July 2009, published on 24. Aug. 2009
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected on 13 and 14 October 2014 / signed on 08 April 2015
Type of method:
static method
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
712 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
870 Pa

Table 4.6/2: Calculated values for 1/T and log P

n                  

Temperature T (°C)

Pressure P (hPa)

Temperature T (K)

1/T (1/K)

log P

(log Pa)

1

20.0

6.3

293.15

0.00341122

2.7993

2

28.9

10.4

302.05

0.00331071

3.0170

3

38.0

15.2

311.15

0.00321388

3.1818

4

47.0

19.9

320.15

0.00312354

3.2989

5

56.0

25.6

329.15

0.00303813

3.4082

6

48.0

20.5

321.15

0.00311381

3.3118

7

39.0

13.4

312.15

0.00320359

3.1271

8

30.0

11.0

303.15

0.00329870

3.0414

9

21.0

8.0

294.15

0.00339963

2.9031

10

15.0

5.8

288.15

0.00347041

2.7634

linear regression :

y = -1524.122806 x + 8.051351352

r² = 0.983600103  (> 0.95)

Table 4.6/3: Calculated Values for vapour pressure

Parameter

Value

Vapour Pressure (20 °C)

712 Pa

Vapour Pressure (25 °C)

870 Pa

 

The vapour pressure of the test item was measured using the static method as described in EU method A.4. Ten pairs temperature/vapour pressure were used to calculate a regression from which vapour pressure at ambient temperature could be estimated.

From the measured values, the vapour pressure of the test item was calculated as 712 Pa at 20.0 °C and 870 Pa at 25 °C. The values of the heating and cooling down phase showed good correspondence.

Therefore, the result of the study is considered valid.

Conclusions:
The vapour pressure of the test item was calculated as 712 Pa at 20.0 °C and 870 Pa at 25 °C (interpolation).
These values represent the components with the highest vapour pressure.
Executive summary:

The vapour pressure of the test substance was measured under GLP according to OECD 104 / EU A4 guideline, static method. Ten pairs temperature/vapour pressure were used to calculate a regression in a temperature range of 15.0 – 56.0 °C, from which vapour pressure at ambient temperature could be estimated.

From the measured values, the vapour pressure of the test item was calculated as 712 Pa at 20.0 °C and 870 Pa at 25 °C (interpolation).

These values represent the components with the highest vapour pressure.

Description of key information

The vapour pressure of the test item was calculated as 712 Pa at 20.0 °C and 870 Pa at 25 °C (interpolation).

These values represent the components with the highest vapour pressure.

Key value for chemical safety assessment

Vapour pressure:
712 Pa
at the temperature of:
20 °C

Additional information

A fully reliable experimental study, conducted according to a recognized OECD/EC method and under GLP, is available. Therefore, it is considered as a key study.

 

Note that the result obtained on this kind of substance should be largely influence by small amounts of volatile constituents and these values don't represent the major part of the substance. Therefore the result should be considered with caution when used for subsequent assessment (worst case).