Registration Dossier

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1994
Report Date:
1994

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 301 C (Ready Biodegradability: Modified MITI Test (I))
Deviations:
no
Qualifier:
according to
Guideline:
other:
Deviations:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge, domestic, non-adapted
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
100 mg/L
Based on:
test mat.

Results and discussion

% Degradationopen allclose all
Key result
Parameter:
% degradation (O2 consumption)
Value:
1
Sampling time:
28 d
Remarks on result:
other:
Key result
Parameter:
% degradation (test mat. analysis)
Value:
2
Sampling time:
28 d
Remarks on result:
other:

BOD5 / COD results

BOD5 / COD
Key result
Parameter:
BOD5
Value:
2.5 other:
Remarks on result:
other:

Applicant's summary and conclusion

Validity criteria fulfilled:
yes