Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 608-369-5 | CAS number: 29514-94-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- From 24 May 2016 to 22 March 2017
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- significant methodological deficiencies
- Remarks:
- No deviation from the guidelines was observed during the study. But due to the test item properties it was not possible to validated an analytical method for which accuracy can be demonstrated. Therefore, the analysed test item concentrations are affected by an unknown uncertainty. The test item concentration and the partition coefficient resulting can only be considered as estimated value.
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient - Shake Flask Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- slow-stirring method
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Batch No.of test material: 15072477V3
- Expiration date of the lot/batch: October 2021
- Purity: > 99.5%
Analysis executed on 2016-10-03:
Purity: 99.67% w/w
Organic Impurities: 0.33% w/w
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: In refrigerator (2-8°C) - Analytical method:
- gas chromatography
- Type:
- log Pow
- Partition coefficient:
- 3.2
- Temp.:
- 20 °C
- pH:
- 5.8
- Remarks on result:
- other: n-octanol / water volume ratio :1:1
- Type:
- log Pow
- Partition coefficient:
- 3.1
- Temp.:
- 20 °C
- pH:
- 5.8
- Remarks on result:
- other: n-octanol / water volume ratio :1:1
- Type:
- log Pow
- Partition coefficient:
- 3.3
- Temp.:
- 20 °C
- pH:
- 5.8
- Remarks on result:
- other: n-octanol / water volume ratio :1:2
- Type:
- log Pow
- Partition coefficient:
- 3.2
- Temp.:
- 20 °C
- pH:
- 5.8
- Remarks on result:
- other: n-octanol / water volume ratio :1:2
- Type:
- log Pow
- Partition coefficient:
- 3.4
- Temp.:
- 20 °C
- pH:
- 5.6
- Remarks on result:
- other: n-octanol / water volume ratio :2:1
- Type:
- log Pow
- Partition coefficient:
- 3.7
- Temp.:
- 20 °C
- pH:
- 5.6
- Remarks on result:
- other: n-octanol / water volume ratio :2:1
- Details on results:
- In the chromatograms of the diluted n-octanol stocks solutions, no response was observed at the retention time of the test item. Therefore, recovery was calculated using the nominal concentration of the stock solution. Indeed, when the analysed concentrations were used to determine the recovery of the test samples, very high value have been obtained (more than 230%). This indicate that the concentration found by analysis in the stock solution was underestimated. No explanation for this phenomenon have been found.
The recovery obtained for n-octanol and aqueous samples were very low. As the analytical method wasn't been validated in n-octanol, analysis have been performed to check the influence of n-octanol on the analytical results. Based on the results obtained, it was concluded that the presence of n-octanol didn't cause the low recoveries found.
The low recoveries found are considered to be due to the evaporation of the test item during the study. - Conclusions:
- Due to the issues observed with the analytical method used to quantify the test item in the samples, the partition coefficient can only be estimated.
The Log Kow is estimated to be 3.4 at 20°C - Executive summary:
The partition coefficient of the test item was determined with the shake flask method according to recognized guidelines (OECD 107 and EU A.8 method) and under GLP.
No deviation from the guideline was observed during the test but thestudy had deficiencies whichaffect the reliability of the results.
Indeed, the samples have been analyzed using an analytical method for which accuracy could not be demonstrated.
Moreover some issues were observed:
· Based on the analytical concentration of the stock solution,inconsistent recovery values were obtained (Recovery values calculated basing on analyzed concentrations in stock solutions were more than 230%). This indicates that the concentration found by analysis in the n-octanol stock solution was underestimated. No explanation for this phenomenon have been found.
· Based on the nominal concentration of the stock solution, recovery for the various n-octanol: water ratios tested was relatively low and showed a spread. The low recovery values in comparison to the nominal concentrations are consistent with loss of test item by evaporation.
The log Powvalues were all in the same range and within the range of ± 0.3 log units as required by the guidelines.
As the measurements performed in this study are affected by an unknown uncertainty due to the lack of a reliable analytical procedure, the results obtained in this study have to be considered as estimated values only.
The estimated log of partition coefficient at 20°C is 3.4.
Reference
The samples were analysed using an analytical method for which accuracy could not be demonstrated due to volatility of the test item. Analysed concentrations on n-octanol and aqueous samples as well as recoveries, partition coefficient have to be considered as estimated values.
Description of key information
No reliable measurement of the Partition Coefficient Octanol-Water of SULFONYL VINYL ETHER PERFLUORURATE is available due to the lack of a reliable validated analytical method.
The impossibility of establishing a reliable validated method is due to the test item properties (volatile liquid with limited water solubility).
Key value for chemical safety assessment
Additional information
Due to the substance properties (high volatility, low water solubility) no validated analytical method for the measurement of SULFONYL VINYL ETHER PERFLUORURATE in water and octanol is established.
Nevertheless the partition coefficient of the test item was determined with the shake flask method according to recognized guidelines (OECD 107 and EU A.8 method) and under GLP.
No deviation from the guideline was observed during the test but the study had deficiencies which affected the reliability of the results. Indeed, the samples have been analyzed using an analytical method for which accuracy could not be demonstrated.
Moreover some issues were observed during the performance of the test arising questions on the appropriateness of the experimental procedure on the whole (low recovery ratios based on initial nominal concentrations were observed, supposed to be due to evaporation of the test item during the test; inconsistent results in recovery ratios (> 100%) based on initial analytical concentrations). The encountered issues are considered to be due to the substance properties.
As the measurements performed in this study were affected by an unknown uncertainty, the results obtained in this study have to be considered as estimated values only.
The estimated log of partition coefficient at 20°C was 3.4.
Basing on the above, the result of this test is considered not reliable.
Due to substance properties more accurate results were not expected so the test was not repeated.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.