Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study was conducted according to an internationally recognised method, and under GLP. The test substance is adequately characterised. Therefore, full validation applies.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
no
Type of method:
effusion method: Knudsen cell

Test material

Constituent 1
Reference substance name:
Rye, ext.
EC Number:
290-271-3
EC Name:
Rye, ext.
Cas Number:
90106-48-2
IUPAC Name:
Oligosaccharides and polysaccharides of glucose from Rye
Test material form:
solid: particulate/powder
Details on test material:
- Appearance: white powder
- Storage In darkness at room temperature
- Batch: 16 167
- Manufacturing date: June 2016
- Expiry date: June 2018

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
ca. 85 °C
Vapour pressure:
< 0.001 Pa
Remarks on result:
not determinable because of methodological limitations
Remarks:
The vapour pressure of the test item was considered to be lower than 10-3 Pa at 120 °C and as a consequence largely lower than 10-3 Pa at 20 °C. This value of 10-3 Pa corresponds to the minimal limit of pressure determined by the apparatus.
Key result
Test no.:
#2
Temp.:
ca. 20 °C
Vapour pressure:
< 0.001 Pa

Any other information on results incl. tables

For the assay No. 1, no loss of weight was recorded at 85°C. No degradation of the test item was observed after the experiment; the powder remained beige. The vapour pressure of test item was considered to be lower than 0.001 Pa at 85°C.

For the assay No. 2, a loss of weight was recorded at 120°C. No degradation of the test item was observed after the experiment; the powder remained beige. The vapour pressure of test item was considered to be consequently largely lower than 0.001 Pa at 20°C.

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test item was considered to be lower than 10-3 Pa at 120 °C and as a consequence largely lower than 10-3 Pa at 20 °C.
Executive summary:

The vapour pressure of the test substance was measured according to OECD 104 / EU A4 guideline using a effusion method weight loss. Two determinations were conducted at 85°C and 120 °C. The vapour pressure of the test item was considered to be lower than 10-3 Pa at 85 °C and as a consequence largely lower than 10-3 Pa at 20 °C.