Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-01-03 – 2017-01-03
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
Measurement of resistance to flow using Redwood Viscometer No. 1.

GLP compliance:
no
Type of method:
other: Redwood Viscometer No. 1
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
11.46
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
10.58

Calculation of Dynamic Viscosities:

 

For Test Temperature at 20°C

ν= η/ρ

13.72 =η 0.8355

η = 13.72 x 0.8355

= 11.46 mPa.S

For Test Temperature at 40°C

ν= η/ρ

12.67 =η/ 0.8355

η = 12.67 x 0.8355

= 10.58 mPa.S

Conclusions:
Dynamic viscosity (calculated) of octyl acetate( CAS No. 112-14-1)at 20°C and 40°C is 11.46mPa.S and 10.58mPa.S, respectively.
Executive summary:

The viscosity determination of test substance octyl acetate was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Kinematic viscosity (experimental) of octyl acetate( CAS No. 112-14-1)at 20°C and 40°C is

13.72mm²/secand 12.67mm²/s,respectively.Dynamic viscosity (calculated) of octyl acetate( CAS No. 112-14-1)at 20°C and 40°C is 11.46mPa.Sand

10.58mPa.S, respectively.

Description of key information

The viscosity determination of test substance octyl acetate was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Kinematic viscosity (experimental) of octyl acetate( CAS No. 112-14-1)at 20°C and 40°C is

13.72mm²/secand 12.67mm²/s,respectively.Dynamic viscosity (calculated) of octyl acetate( CAS No. 112-14-1)at 20°C and 40°C is 11.46mPa.Sand

10.58mPa.S, respectively.

Key value for chemical safety assessment

Viscosity:
13.72 mm²/s (static)
at the temperature of:
20 °C

Additional information

The viscosity determination of test substance octyl acetate was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Kinematic viscosity (experimental) of octyl acetate( CAS No. 112-14-1)at 20°C and 40°C is

13.72mm²/secand 12.67mm²/s,respectively.Dynamic viscosity (calculated) of octyl acetate( CAS No. 112-14-1)at 20°C and 40°C is 11.46mPa.Sand

10.58mPa.S, respectively.