Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Between 3 March 2009 and 27 March 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Recently conducted GLP compliant study using the most recent test methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): JKY-214
- Physical state: white solid
- Analytical purity: No information
- Lot/batch No.: Y002E
- Expiration date of the lot/batch: No information
- Stability under test conditions: No information. Assumed stable due to no data to the contrary
- Storage condition of test material: room temperature in the dark
- Other:

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Preliminary screening test

The pile failed to ignite during the two minutes that the Bunsen was applied.

The result of the preliminary screening test obviated the need to perform the main test.

Moisture content

 

Determination A

Determination B

a) Mass of loss bottle (g)

19.4714

19.6938

b) Mass of loss bottle and test material (g)

20.4334

20.6604

c) Mass of loss bottle and test material after drying (g)

20.4321

20.6592

Moisture content (% w/w)

0.135

0.124

Mean moisture content (% w/w)

0.130

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information The test sample failed to ignite
Conclusions:
The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.
Executive summary:

The flammability has been assessed by means of measuring the combustion of the material according to EU method A10 in compliance with GLP. Combustion of a determined pile of test sample was attempted by application of an air rich flame from a bunsen burner for a period of 2 minutes. The pile failed to ignite and the test sample is therefore considered to be not flammable.