Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Endpoint summary

Administrative data

Description of key information

Daphnia:

Three studies are available to evaluate the acute toxicity to aquatic invertebrates

1) Key Study on a similar substance: Experimental study, guideline EPA OPPTS 850.1010, performed under GLP conditions.

The test item is the substance 2-ethyl-4-(2,2,3-trimethyl-3-cyclopenten-1-yl)-2-buten-1-ol (CAS 28219-61-6; EC 248-908-8).

Result is EC50(48h) = 1.4 mg/L

2) Supporting QSAR estimation on a similar substance: Estimation done with  ECOSAR v1.11 (QSAR model from the U.S. EPA)

The substance used for the calculation is 2-ethyl-4-(2,2,3-trimethyl-3-cyclopenten-1-yl)-2-buten-1-ol (CAS 28219-61-6; EC 248-908-8).

Result is EC50(48h) = 1.03 mg/L

3) Supporting QSAR estimation on the substance under registration (i.e as defined in section 1 of this dossier).

Estimation done with  ECOSAR v1.11 (QSAR model from the U.S. EPA)

Result is EC50(48h) = 1.7 mg/L

Fish:

The following LC-values were determined:

LC0 = 2.6 mg/L

LC50 = 6.3 mg/L

LC100 = 8.5 mg/L

Algae:

Three studies are available to evaluate the toxicity to aquatic algae:

1) Key Study on a similar substance: Experimental study, guideline EPA OPPTS 850.5400, performed under GLP conditions.

The test item is the substance 2-ethyl-4-(2,2,3-trimethyl-3-cyclopenten-1-yl)-2-buten-1-ol (CAS 28219-61-6; EC 248-908-8).

Result is EC50(96h) = 2.5 mg/L, NOEC(96h)=0.4 mg/L

2) Supporting QSAR estimation on a similar substance: Estimation done with  ECOSAR v1.11 (QSAR model from the U.S. EPA)

The substance used for the calculation is 2-ethyl-4-(2,2,3-trimethyl-3-cyclopenten-1-yl)-2-buten-1-ol (CAS 28219-61-6; EC 248-908-8).

Result is EC50(96h) = 1.9 mg/L

3) Supporting QSAR estimation on the substance under registration (i.e as defined in section 1 of this dossier).

Estimation done with  ECOSAR v1.11 (QSAR model from the U.S. EPA)

Result is EC50(96h) = 2.8 mg/L

Microorganismes:

The following effect concentrations were determined:

EC0: 30 mg/L

EC10: 100 mg/L

Additional information