Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 16, 2003 - December 17, 2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed in accordance with EU Method A.10 (1992) and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report Date:
2004

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
(1992)
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Leuchtstoff L 165
- Appearance: white, fine crystalline solid

Results and discussion

Any other information on results incl. tables

The test substance did not ignite. The surface layer of the test substance only glowed in orange-red colour under direct contact of the burner flame. No smoke was noticed. The burner flame was extinguished after 2 minutes. The test resulted in an unaltered sample heap.

Applicant's summary and conclusion

Interpretation of results:
other: 'not highly flammable' by ignition
Conclusions:
The substance was determined to be 'not highly flammable' by ignition in a GLP-compliant study performed in accordance with EU Method A.10 and according to GLP principles.