Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Too few particles were of a size less than 10.0 µm to allow accurate assessment of the mass median aerodynamic diameter.

Additional information

Particle size data was acquired using a procedure designed to be compatible with the European Commission Technical Guidance Document EUR 20268 'Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances' (2002). The results are as follows:

Measurement

Method

Result

Proportion of test item having an inhalable particle size <100 µm

Sieve

14.8%

Proportion of test item having a thoracic particle size <10.0 µm

Cascade Impactor

0.736%

Proportion of test item having a respirable particle size <5.5 µm

Cascade Impactor

0.185%