Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13-18.03.2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP - Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
column elution method

Test material

Constituent 1
Chemical structure
Reference substance name:
N-(4-{[3-(dimethylamino)propyl]sulfamoyl}phenyl)-2-[(2-methoxy-4-nitrophenyl)diazenyl]-3-oxobutanamide
EC Number:
700-222-4
Cas Number:
1065519-44-9
Molecular formula:
C22H28N6O7S
IUPAC Name:
N-(4-{[3-(dimethylamino)propyl]sulfamoyl}phenyl)-2-[(2-methoxy-4-nitrophenyl)diazenyl]-3-oxobutanamide
Details on test material:
- Name of test material (as cited in study report): No. 408 Yellow
- Physical state: Yellow powder
- Analytical purity: 98.6%
- Lot/batch No.: 081105-1
- Expiration date of the lot/batch: 04.11.2009
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Water solubility
Water solubility:
ca. 19.8 µg/L
Temp.:
20.3 °C
pH:
>= 7.1 - <= 7.2
Details on results:
The results for the samples taken at a flow rate of 12 and 24 ml/h are given in Table 1. The water solubility is given as a mean value of the measurements at both flow rates, because the coefficient of variation for both flow rates (CV) (n=10) and maximum difference on the water solubility was <30%. No undissolved particles were present in eluates.
The results of the accuracy samples are shown in Table 2.
The mean accuracy (value above the range 70-110%) was used to correct the water solubility data present in Table 1.

Any other information on results incl. tables

Table 1:

Flow rate [ml/h]

Sample no.

Concentration analysed

pH

Individual [mg/l]

Mean 1 [mg/l] at one flow rate

Mean 2 [mg/l] at one flow rate corrected for the mean recovery of the procedural recovery samples (113%)

CV [%]

24

1

0.0196

0.0231

0.0204

15

7.1

2

0.0203

3

0.0214

4

0.0203

5

0.0191

6

0.0235

7

0.0256

8

0.0291

9

0.0281

10

0.0239

12

1

0.0249

0.0217

0.0192

12

7.2

2

0.0196

3

0.0208

4

0.0194

5

0.0249

6

0.0212

7

0.0176

8

0.0236

9

0.0208

10

0.0248

Mean of all concentrations, corrected for the mean recovery of the procedural recovery samples (113%): 0.0198 mg/l, MD: 6%

Table 2:

Target concentration [μg/l]

Nominal concentration [μg/l]

Analysed concentration [μg/l]

Accuracy [%]

Mean accuracy [%]

22

22.1

24.9

25.1

113

114

113

 