Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 275-833-8 | CAS number: 71675-87-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- flammable solids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 17 September 2014
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.10 (Flammability (Solids))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Name of test material (as cited in study report):4-amino-5(ethylsulphonyl)-o-anisic acid
- Physical state:Solid
- Analytical purity: 99.81%
- Lot/batch numberl:MP1032.31 - Key result
- Test procedure:
- burning rate test: preliminary screening test
- Remarks on result:
- other: The sample does not ignite after 30, 60 nor 120 minutes.
- Interpretation of results:
- GHS criteria not met
- Remarks:
- Non flammable
- Conclusions:
- Test item was not highly flammable in accordance with test EU Method A.10. criteria.
- Executive summary:
Flammability (solids) test was performed according to the EU Method A.10 and GLP study. After application of the flame of burner for 30, 60 and 120 seconds (triplicate), the sample does not ignite but it melts. The preliminary results were negative therefore, it was not necessary to go to the next stage of determination. Test item was not highly flammable in accordance with test EU Method A.10. criteria.
- Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
Study scientifically not necessary / other information available: The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water. The test substance is therefore regarded as not being flammable in contact with water. - Endpoint:
- pyrophoric solids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
study scientifically not necessary / other information available: The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing. Moreover, according to the auto-ignition study on test item, the substance does not ignite in air at ca. 20 °C and even not at temperatures up to 400 °C. The test substance is therefore regarded as not being pyrophoric.
Referenceopen allclose all
After applying the flame of burner the sample does not ignite but it melts. Application time of the ignition source was 30, 60 and 120 seconds. The preliminary results were negative, therefore it was not necessary to go to the next stage of determination. Test item was not highly flammable in accordance with test EU Method A.10. criteria.
Description of key information
Key study: Test method EU Method A.10. GLP study. Test item was not highly flammable in accordance with test criteria.
Flammability in contact with water: Data waiving: Based on experience, the substance is not regarded as flammable in contact with water.
Pyrophoricity: Data waiving: Based on experience, the substance is regarded as not pyrophoric.
Key value for chemical safety assessment
- Flammability:
- not classified
Additional information
Key study: Flammability (solids) test was performed according to the EU Method A.10. After application of the flame of burner for 30, 60 and 120 seconds (triplicate), the sample does not ignite but it melts. The preliminary results were negative. Test item was not highly flammable in accordance with test EU Method A.10. criteria.
Flammability in contact with water: Data waiving : The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water. The test substance is therefore regarded as not being flammable in contact with water.
Pyrophoricity: Data waiving: The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing. Moreover, according to the auto-ignition study on test item, the substance does not ignite in air at ca. 20 °C and even not at temperatures up to 400 °C. The test substance is therefore regarded as not being pyrophoric.
Justification for classification or non-classification
Based on the available information, the test item is not classified according to CLP Regulation (EC) no. 1272/2008.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.