Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Scientifically acceptable study without detailed documentation according to a BASF standard method.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Guideline:
other: not reported
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Diethylenglycoldivinylether
- Analytical purity: not indicated
- Impurities: Diethylenglycolmonovinylether
- Lot/batch No.: DVE-2 S01 Kopf

Results and discussion

For thermal stability study

Test substance thermally stable:
no
Operating temperature
Operating temp.:
30 - 500 °C
Remarks on result:
other: 1st reaction onset temperature 125 °C, peak temperature 145 °C, energy release 50 J/g, 2nd reaction onset temperature 220 °C, peak temperature 363 °C, energy release 740 J/g

Any other information on results incl. tables

Test parameters
Apparatus: Mettler TA 8000
Sample containers: pressure resistant, V2A
Sample weight: 17.3 mg
Reference material: empty container
Heating rate: 2.5 °C/min
Temperature range: from 30 °C to 500 °C
Results
1st reaction:
Onset temperature: 125 °C
Peak temperature: 145 °C
Energy release: 50 J/g
2nd reaction:
Onset temperature: 220 °C
Peak temperature: 363 °C
Energy release: 740 J/g

Applicant's summary and conclusion